Various options
Variants
The industrial air curtain is available in two capacities: S(mall) and M(edium). There
are two lengths to choose from; 1.5 and 2.0 metres, and by combining these two
types, any desired discharge width or height, from 3.0m, can be achieved in 0.5m
increments. Both types are supplied with a water heating coil, an electric heating
coil, or without any heating coil (ambient). The IndAC can be positioned horizontally
and vertically (see page 7). Further, the device is available with a Basic, Plus or
Automatic control unit (see page 8).
Standard delivery and accessories
Model IndAC is delivered with:
two suspension brackets - for horizontal installation
two coupling plates - for vertical installation
wall bracket - for vertical installation
connection cable to interlink adjoining units
These components are also needed:
Basic, Plus or Automatic controller
base plate / plinth - for vertical installation
Options:
door contact switch
room thermostat
Flexible suspension system
With horizontal installation, the unit is suspended above the door by using four
threaded rods (M12) and the suspension brackets supplied (see picture alongside).
As a flat surface is essential with vertical installation, it is recommended to place
the IndAC on a base plate. By using the supplied coupling plates and wall bracket it
is easy to fix and secure the unit.
Typecode
IndAC S-150-W1-2R
Capacity
S = S(mall)
M = M(edium)
L = L(arge)*
Unit length
150 = 150 cm
200 = 200 cm
Coil type
W1 = Water heating -
high water temperatures
W2 = Water heating -
medium water temperatures
W3 = Water heating -
low water temperatures
E = Electrical heating
A = Ambient, no heating coil
Installation position
0 = Horizontal, above door
1R = Vertical, right side, square to wall
1L = Vertical, left side, square to wall
2R = Vertical, right side, parallel to wall
2L = Vertical, left side, parallel to wall
1
From 3.0m, any combination of the two unit lengths is possible.
* The L-type will be available by mid-2007.
Type Unit length
1
Coil type Installation positions
IndAC S 150 W (water) Horizontal
IndAC M 200 E (electric) Vertical
A (ambient) - right or left
- square or parallel
to wall