Biddle CA2 Spezifikationen Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
9
Technical & Performance
Specifications
Invisidor CA2-L
I
deal for mounting up to 3.3m from floor to discharge
Next generation of air curtains - available today
Sets new standards of performance and efficiency
Large Retail Outlets/Superstores/Leisure Complexes (2,000m
2
-6,000
2
m)
Brings high-tech appeal to any entrance
Maximum Installation Height m
Optimum Door Width m
Unit Width m
Heating Capacity Strength 1 kW
2
3
4
5
6
Air Volume Strength 1 m
3
/s
2
3
4
5
6
W
ater Flow Rate
l/s
Coil Hyd Pressure Drop (Max) kPa
Electrical Supply
Max P
ower kW
Max Running Current A
Noise Level at 3m
@Strength 3
dB(A)
Weight (Dry) Model F kg
Model R
Model R(0)
Model C
CA2-L CA2-L CA2-L CA2-L CA2-L CA2-L CA2-L CA2-L
100 W 150 W 200 W 250 W 100 E 150 E 200 E 250 E
3.3
3.3 3.3 3.3 3.3 3.3 3.3 3.3
0.8 1.3 1.8 2.3 0.8 1.3 1.8 2.3
1.0 1.5 2.0 2.5 1.0 1.5 2.0 2.5
5.8 8.6 11.6 14.4 5.8 8.6 11.6 14.4
7.6 11.4 15.2 19.0 7.6 11.4 15.2 19.0
9.5 14.3 19.1 23.8 9.5 14.3 19.1 23.8
12.3 18.4 24.5 30.7 12.3 18.4 24.5 30.7
14.5 21.7 28.9 36.1 14.5 21.7 28.9 36.1
22.1 33.2 44.2 55.3 22.1 33.2 44.2 55.3
0.318 0.476 0.636 0.794 0.318 0.476 0.636 0.794
0.419 0.627 0.838 1.047 0.419 0.627 0.838 1.047
0.525 0.786 1.048 1.311 0.525 0.786 1.048 1.311
0.675
1.012
1.350
1.688
0.675
1.012
1.350 1.688
0.796 1.193 1.591 1.988 0.796 1.193 1.591 1.988
0.912 1.369 1.826 2.281 0.912 1.369 1.826 2.281
0.27
0.40
0.54
0.67 n/a n/a n/a n/a
2.9 7.6 16.4 11.1 n/a n/a n/a n/a
0.71 1.06 1.41 1.76 24.5 36.4 49.0 60.9
3.19
4.78
6.37
7.96
3x37.9 3x56.3 3x75.8 3x94.2
46
48
49
50 46 48 49 50
65 96 122 155 69 104 137 170
83 121 156 198 87 129 171 213
74 110 140 178 79 118 156 194
81 118 152 192 85 126 167 205
W
ater Heating
Electrical Heating
Model
230v/1ph/50Hz
400v/3ph/50Hz
82/71°C 1.00 1.00 1.00 1.00
70/50°C 1.00 1.00 1.00 1.00
60/40°C 0.69 0.82 0.89 0.80
CA2 L-250 WCA2 L-200 W
CA2 L-150 W
CA2 L-100 W
Heating Capacities based on flow and return temperatures of 80/60°C, 20°C entering air and air outlet temperatures of:
•Strengths 1.5 = 35°C
•Strength 6 = 40°C
In operation, the outlet temperatures will vary between 20-50°C max
Correction Factors for other water flow temperatures
Note: Factors to be applied to the heating capacity at Strength 6 only
Specification
Codes
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare