Technical & Performance
Specifications
Invisidor CA2-XL
H
igher performance without the need for a larger unit
Specifically designed to cope with up to 4m high doors or complex entrance
environments
Large Retail Outlets/Hypermarkets/Department Stores/Shopping Centres with
higher performance requirements (5,000m
2
plus)
Maximum Installation Height m
Optimum Door Width m
Unit Width m
Heating Capacity Strength 1 kW
2
3
4
5
6
Air Volume Strength 1 m
3
/s
2
3
4
5
6
W
ater Flow Rate
l/s
Coil Hyd Pressure Drop (Max) kPa
Electrical Supply
Max P
ower kW
Max Running Current A
Noise Level at 3m
@Strength 3
dB(A)
Weight (Dry) Model F kg
Model R
Model R(0)
Model C
CA2-XL CA2-XL CA2-XL CA2-XL CA2-XL CA2-XL CA2-XL CA2-XL
100 W 150 W 200 W 250 W 100 E 150 E 200 E 250 E
4.0
4.0 4.0 4.0 4.0 4.0 4.0 4.0
0.8 1.3 1.8 2.3 0.8 1.3 1.8 2.3
1.0 1.5 2.0 2.5 1.0 1.5 2.0 2.5
6.9 10.4 13.8 17.3 6.9 10.4 13.8 17.3
9.1 14.0 18.3 22.9 9.1 14.0 18.3 22.9
11.6 17.4 23.1 28.9 11.6 17.4 23.1 28.9
15.0 22.5 30.0 37.6 15.0 22.5 30.0 37.6
17.8 26.8 35.7 44.6 17.8 26.8 35.7 44.6
26.8 40.2 53.6 67.0 23.5 34.6 46.6 57.9
0.380 0.571 0.761 0.951 0.380 0.571 0.761 0.951
0.504 0.757 1.009 1.261 0.504 0.757 1.009 1.261
0.637 0.956 1.273 1.593 0.637 0.956 1.273 1.593
0.826
1.240
1.653
2.066
0.826
1.240
1.653 2.066
0.982 1.472 1.962 2.452 0.982 1.472 1.962 2.452
1.105 1.658 2.212 2.765 1.105 1.658 2.212 2.765
0.33
0.49
0.65
0.82 n/a n/a n/a n/a
4.3 10.9 22.9 16.8 n/a n/a n/a n/a
1.17 1.75 2.34 2.92 24.5 36.4 49.0 60.9
5.27
7.91
10.54
13.18
3x38.6 3x57.5 3x77.3 3x96.1
52
53
55
56 52 53 55 56
69 102 131 164 73 110 146 179
87 127 165 207 91 135 180 222
78 116 149 187 83 124 165 203
85 124 161 201 89 132 176 216
W
ater Heating
Electrical Heating
Model
230v/1ph/50Hz
400v/3ph/50Hz
82/71°C 1.00 1.00 1.00 1.00
70/50°C 1.00 1.00 1.00 1.00
60/40°C 0.63 0.75 0.82 0.74
CA2 XL-250 WCA2 XL-200 W
CA2 XL-150 W
CA2 XL-100 W
Heating Capacities based on flow and return temperatures of 80/60°C, 20°C entering air and air outlet temperatures of:
•Strengths 1.5 = 35°C
•Strength 6 = 40°C
In operation, the outlet temperatures will vary between 20-50°C max
Correction Factors for other water flow temperatures
Note: Factors to be applied to the heating capacity at Strength 6 only
Specification