INSTALLATION COMFORT AIR CURTAIN
en-18
en
2.7 Installing the control panel and external controls
2.7.1 Control panel details
Positioning
• You may fix the control panel either to the wall or to a
standard socket.
Cabling
n Take the following into account, otherwise faults may
occur:
- Keep control cables away from electromagnetic fields
and interference sources such as high-voltage cables
and fluorescent-light starters.
- Stretch control cables out or roll them up neatly.
- The control cable between the control panel and the
connected unit may not be any longer than 30 m.
n Use Biddle control cables only (Type RJ4). Standard
modular telephone cable is not suitable.
See also:
2.7.6 "Multiple units operated from one control panel" on
page 21
2.7.2 Control panel settings
Optional
Several dip switches are located inside the control panel.
These allow the control panel to be configured.